eXpress

  Help

×
Menu
Index
 

Test Weightings - Viewing

 

Feature Description

 
Although analyses are often based on the default test weighting definitions for the selected diagnostic algorithm, many Analysts may wish to review and possibly edit these weighting definitions.
 

How To View Weightings

 
1
Choose the "Detection Options" or "Isolation Options" tab within the context panels.
2
Select the desired diagnostic algorithm using the dropbox at the top of the panel.
3
Click on the first entry in the Weightings column in the grid on the left-hand side of the panel (this cell contains a count of the number of weighting definitions for the selected algorithm).
4
The weightings definitions for the selected algorithm will display in the window on the right-hand side of the panel. Open the folder associated with each weighting definition to view the assigned weighting parameter Test limits.
 
 
Note: A text description of each weighting appears in the Weighting Parameters dialog (which appears when a weighting definition is edited). Analysts may therefore wish to review a weighting definition by invoking this edit dialog.